Important Information

 

Thank you for purchasing our product. If there are any questions, please contact the authorized dealer.

 

Before operating the unit, please read this manual thoroughly and retain it for future reference.
 

Copyright
Copyright 2015-2026 Bolin Technology, all rights reserved. No part of this manual may be copied, reproduced, translated, or distributed in any form or by any means without prior consent in writing from our company.
 

Trademark Acknowledgment
Bolin Technology's trademarks and logos are the property of Bolin Technology. Other trademarks, company names and product names contained in this manual are the property of their respective owners.
 

Trademarks and Registered Trademark Acknowledgment
• Microsoft, Windows, ActiveX, and Internet Explorer are registered trademarks of Microsoft Corporation in the U.S. and/or other countries.
• HDMI, the HDMI logo and High-Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing, LLC in the United States and other countries.
• The Software may contain h.264/AVC video technology, the use of which requires the following notice from MPEG-LA, L.L.C.:

THIS SOFTWARE IS LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE FOR THE PERSONAL AND NON-COMMERCIAL USE OF A CONSUMER TO (I) ENCODE VIDEO IN COMPLIANCE WITH THE AVC STANDARD ("AVC VIDEO") AND/OR (II) DECODE AVC VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NON-COMMERCIAL ACTIVITY AND/OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC VIDEO. NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE. ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA, L.L.C. SEE http://www.mpegla.com.

• HEVC/H.265 Covered by one or more claims of patents listed at patentlist.hevcadvance.com
• HDBaseT is a trademark of the HDBaseT Alliance.
• ONVIF trademarks and logos are to be used per the guidelines established in this and other ONVIF policies and documents, including the ONVIF Rules of Membership and the ONVIF Logo Guidelines1.
• Other trademarks, company names and product names contained in this manual are the property of their respective owners.

• NDI® is a registered trademark of Vizrt NDI AB.

 

Legal Notice
 

Attention:

To ensure account security, the user should change the password after their first login. The user is recommended to set a strong password (no less than eight characters). Password login does not apply to certain models that do not require password login.

 

The contents of this document are subject to change without prior notice. Updates will be added to the new version of this manual. Improvements or updates to the products or procedures described in the manual will be made readily.

 

The best effort has been made to verify the integrity and correctness of the contents in this document, but no statement, information, or recommendation in this manual shall constitute a formal guarantee of any kind, expressed or implied. Responsibility for any technical or typographical errors in this manual will not be held.

The product appearance shown in this manual is for reference only and may be different from the actual appearance of the user’s device.

 

This manual is a guide for multiple product models and so it is not intended for any specific product.

 

In this manual, the illustrations of the displayed interface, parameters displayed, drawings, and value ranges may vary with models. The user should refer to the actual product for details.

 

Due to uncertainties such as the physical environment, discrepancies may exist between the actual values and reference values provided in this manual.

Use of this document and the subsequent results shall be entirely at the user’s own responsibility.

 

Before operating the unit, the user should read this manual thoroughly and retain it for future reference.

 

Important Safety and Usage Notices

 

WARNING: Contains important safety instructions and indicates situations that may cause bodily injury.
CAUTION: Users must be careful. Improper operations may cause damage or malfunction of product.
NOTE: Indicates useful or supplemental information about the use of the product. 

 

Safety Information

 

WARNING: Installation and removal of the unit and its accessories must be carried out by qualified personnel. You must read all of the Safety Instructions supplied with your equipment before installation and operation.

 

• If the product does not work properly, please contact your dealer. Never attempt to disassemble the camera yourself. (We will not assume any  responsibility for problems caused by unauthorized repair or maintenance.)
• This installation should be made by a qualified service person and should conform to all the local codes.
• When shipping, the camera should be packed in its original packaging.
• Make sure the power supply voltage is correct before using the camera.

• Do not drop the camera or subject it to physical shock.
• Do not touch sensor modules with fingers. If cleaning is necessary, use a clean cloth with a bit of ethanol and wipe it gently. If the camera will not be used for an extended period of time, put on the lens cap to protect the sensor from dirt.
• Do not aim the camera lens at strong light such as the sun or incandescent lamp. The strong light can cause fatal damage to the camera.

 

Maintenance Precautions:
• If there is dust on the front glass surface, remove the dust gently using an oil-free brush or a rubber dust blowing ball.
• If there is grease or a dust stain on the front glass surface, clean the glass surface gently from the center outward using anti-static gloves or an oil-free cloth. If the grease or the stain still cannot be removed, use anti-static gloves or an oil-free cloth dipped with detergent and clean the glass surface gently until it is removed.
• Do not use organic solvents, such as benzene or ethanol, when cleaning the front glass surface.

 

Regulatory Compliance


FCC Part 15

 

This equipment has been tested and found to comply with the limits for digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

 

This product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

 

This device may not cause harmful interference.

 

This device must accept any interference received, including interference that may cause undesired operation.

 

CE LVD/EMC Directive
This product complies with the European Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC.
WEEE WEEE Directive–2002/96/EC
The product this manual refers to is covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner.

 

 

 

Lightbox content

 

What's In the Box

 

R9-420N - 1 Inch 4K PTZ Camera

DSC_0035_Plug P12-4L - Camera Power Adapter 12VDC 4A with Lock
VCC-RC-2 - Bolin R2 IR Remote Controller
VCC-CC45RS - RJ45 to Serial Control Cable Adapter
72mm Lens Cap
DSC_0028r Bolin Protective Dust Cover
Safety Cable
HDMI Cable Support with Screws

 

Optional Accessories

 

C-WM3B or C-WM3W - Large PTZ Camera Wall Mount Bracket - Black or White

C-WM3B-CV or C-WM3W-CV - Cover Set for Large PTZ Camera Wall Mount Bracket - Black or White

C-PMSB or C-PMSW - PTZ Camera Pendant Mount System for Drop Ceiling - Black or White

Pendant Mount Base Adaptor, Bolin C-PMBA C-PMBA - Pendant Mount Base Adaptor
PTZ Quick Release Plate, Bolin QR-M QR-M - Quick Release Plate for Indoor PTZ Cameras
BL-CM-01 - Indoor PTZ Ceiling Mount Bracket
   
BLA-10 - 10-Pin LEMO to Balanced XLR Connector
B-OSM-12 - Optical 12G-SDI SFP Transceiver

 

Recommended Peripherals

 

BL-PP97 - 97W POE Injector 
DSC_8573-tally800x800new

EG40F - FAST HEVC 4K60 IP Video Decoder

EG40N - High Bandwidth NDI Decoder

KBD-1020N - PTZ Camera Controller

KBD-PLUS-Front-Right-Power-On-01(1) KBD PLUS - Advanced PTZ Production Controller
 

 

Overview

 

This user guide will provide users of the R9-420N indoor PTZ cameras with in-depth knowledge of the various features and functions of the camera and how it can be utilized. Functions limited to a specific camera model will be noted as such in the various sections. 

 

Lightbox content

 

Camera Diagrams and Dimensions

 

R9_Diagram_and_dimensions_-_1

R9_Diagram_and_dimensions_-_2_copy

 

NOTE: All dimensions listed below are in millimeters.

                                                                             

 

 

 

Quick Start Guide

 

The R9 Series Indoor PTZ Camera has multiple connection options for video output, power input, control input, audio input and output, and synchronization. You can choose the appropriate connection points based on your requirements.

 

 

Power Options

 

 

 

Network Connection Options

This camera offers a variety of functionalities via a network connection. Besides being powered over Ethernet, a network connection enables the user to adjust camera settings remotely, stream video from the camera to a distant location, and control the PTZ camera functions via the Web Interface. To set up your camera’s network connection, choose one of the following methods:

 

Option 1: Using the Power Adapter and a Network Switch

  1. Connect the provided power adapter to the camera’s DC input.
  2. Use a Cat6 Ethernet cable to connect the camera’s LAN port to a standard network switch.
  3. Ensure the network switch is connected to your network for data transmission.

Option 2: Using a PoE++ Network Switch (Single Cable Connection)

  1. Connect a Cat6 Ethernet cable from the camera’s LAN/PoE++ port directly to a PoE++-enabled network switch.

Benefit: The PoE++ switch powers the camera and transmits data through a single cable, reducing cable clutter and simplifying installation.

Option 3: Using the Bolin PoE Injector (BL-PP97) for Extended Distance

  1. Connect a Cat6 Ethernet cable from the PoE injector’s PoE output to the camera’s LAN/PoE++ port.
  2. Connect another Cat6 Ethernet cable from the PoE injector’s Data In port to a network switch.
  3. Plug the DC power adapter into the PoE injector.

 

 

Locating a Bolin camera on the Network

By default, most Bolin cameras are configured with the following static IP address:

Default IP Address: 192.168.0.13

Exception: Dante and NDI enabled camera models are configured to use DHCP by default and will automatically obtain an IP address from a DHCP server when connected to a network.

 

Use one of the following methods to locate and access your camera.

1. Using the Bolin Discovery Tool

The Bolin Discovery Tool is the recommended method for locating Bolin cameras on a network.

  1. Download and install the Bolin Discovery Tool - Windows from the Bolin website. (Bolin Discovery Tool v2.0 - MacOS)
  2. Connect your computer and camera to the same network.

Alternatively, the camera can be connected directly to the computer's Ethernet/LAN port. When using a direct connection, power the camera using the supplied power adapter.

  1. Launch the Bolin Discovery Tool.
  2. The tool will scan the network and display detected Bolin cameras along with information such as their assigned IP addresses.
  3. Select the desired camera to identify its current network settings.
NOTE: When connecting directly to a camera configured with the default static IP address, the computer's network adapter must be configured within the same IP subnet.

 

2. Accessing the Camera Manually Using a Web Browser

For cameras using the default static IP address:

  1. Configure the computer's Ethernet adapter with an IP address within the same subnet as the camera. For example:
    • Computer IP Address: 192.168.0.X
    • Subnet Mask: 255.255.255.0
  2. Open a supported web browser.
  3. Enter the camera's default IP address in the address bar:

192.168.0.13

  1. When the camera's Web GUI opens, log in using the default credentials or the credentials previously configured for the camera.
IMPORTANT: Do not assign 192.168.0.13 to the computer, as this address is already assigned to the camera. Each device on the network must have a unique IP address.

 

3. Using an IP Scanner Utility

A third-party network/IP scanning utility can also be used to locate devices on the network.

  1. Connect the computer to the same network as the camera.
  2. Run the IP scanner and scan the appropriate network range.
  3. Review the detected devices to identify the camera and its assigned IP address.

Depending on the scanning utility, the camera may appear under the manufacturer name Bolin or by its configured hostname.

 

4. Checking the IP Address Through the Camera OSD Menu

If the camera is connected to a display, its current IP address can also be viewed through the camera's On-Screen Display (OSD) Menu.

  1. Point the IR remote controller toward the camera.
  2. Open the camera's OSD Menu.
  3. Navigate to STATUS.
  4. Locate the network information to view the camera's current IP address and other network settings.
NOTE: An IR remote controller is not included with the SD530 and EX1030 Series cameras.

 

Network Connection Note
The computer and camera must be on the same network/subnet to communicate directly.
For cameras using the default static IP address of 192.168.0.13, configure the computer with a unique address in the 192.168.0.X range and use a subnet mask of 255.255.255.0.
For DHCP-enabled cameras, the assigned IP address will depend on the network's DHCP server. Use the Bolin Discovery Tool or the camera's OSD Status menu to determine the assigned address.

 

 

Video Output 

The PTZ camera has multiple video outputs, which can be used simultaneously, and the resolutions can be configured independently. The outputs vary based on the camera model and are as follows: 

 

IP Stream Out

The camera’s IP stream(s) can be configured through its web interface. To access the web interface, the camera must be connected to a Local Area Network (LAN) using a CAT6 cable, either through a network switch or directly to a computer. Streaming to the Internet also requires an active internet (WAN) connection.

Follow these steps to set up IP streaming:

  1. Connect the Camera to the Network – Plug one end of a CAT6 cable into the camera’s LAN/PoE++ port and connect the other end to either a network switch or directly to a computer.

  2. Access the Web Interface – On a computer, open an HTML5-enabled web browser and enter the camera’s IP address. By default, the camera is set to DHCP, so the IP address is assigned by the network.

  3. Enable and Configure Streaming – In the web interface, navigate to the "AV Setup" menu on the left side. From here, enable and adjust the IP stream settings as needed.

HDMI Out

Follow these steps to connect the camera:

  1. Connect the HDMI Cable – Plug one end of an HDMI cable (compatible with the required resolution) into the camera’s HDMI output. Connect the other end to your desired device, such as a switcher, converter, or display.

  2. Power On the Camera – Turn on the camera and wait for it to initialize. Once it's ready, the video feed will appear on the screen. During the first five seconds, the camera’s initial settings will be displayed.

  3. Adjust Output Settings – Use the OSD (On-Screen Display) menu or the web interface to configure the output resolution and frame rate as needed. For detailed instructions, refer to the Web Interface Configuration section of this guide.

NOTE: It is recommended for the user to utilize a certified “Premium High Speed HDMI” cable to guarantee the attainment of the maximum signal quality from their camera.

 

HDMI Standard Bandwidth Max Resolution Supported
HDMI 1.4 10.2 Gigabits/Second

1080p, 120 Hz

4K, 30 Hz

HDMI 2.0 18.0 Gigabit/Second 4K, 60 Hz
HDMI 2.1 48.0 Gigabit/Second 8K, 120 Hz

 

SDI Out

Follow these steps to connect the camera:

  1. Connect the SDI Cable – Plug one end of a properly rated SDI cable into one of the camera’s two SDI outputs. Make sure the BNC connector is securely fastened to prevent it from coming loose during use. Connect the other end to your desired device, such as a switcher, video router, converter, or display.

  2. Power On the Camera – Turn on the camera and allow it to initialize. Once ready, the video feed will appear on the screen. For the first five seconds, the camera’s initial settings will be displayed.

  3. Adjust Output Settings – Use the OSD (On-Screen Display) menu or the web interface to configure the output resolution and frame rate. For detailed instructions, refer to the Web Interface Configuration section of this guide.

NOTE: It is recommended to use a high-quality, shielded SDI cable rated for the required resolution and transmission distance to ensure optimal signal integrity and reliability.

 

 

The following table is for general reference only. Supported resolutions and frame rates vary by camera model. Refer to your camera’s datasheet to confirm its SDI output specifications:

SDI Standard Bandwidth Resolution Supported
SD-SDI 270 Megabits/Second

480i

HD-SDI 1.485 Gigabit/Second 720p / 1080i
3G-SDI 2.970 Gigabit/Second 1080P, 60FPS
6G-SDI 6 Gigabit/Second 4K, 30FPS
12-SDI 12 Gigabit/Second 4K, 60FPS

 

Optical Fiber

Follow these steps to set up a fiber connection for your camera:

  1. Obtain the Necessary Components – Acquire two single-mode 1310 nm SFP+ 12G optical modules (transceivers) with LC duplex fiber connectors—one for each end of the signal chain. Additionally, select a single-mode duplex fiber cable with LC connectors that meets your required length.

  2. Install the SFP+ Modules – Insert one SFP+ module into the camera’s fiber port. Ensure it is fully seated before proceeding. Then, connect one end of the fiber cable to the LC connectors on the module.

  3. Repeat at the Receiving End – Insert the second SFP+ module into the receiving device (such as a fiber converter, monitor, or recorder) and connect the other end of the fiber cable.

  4. Power On the Camera – Turn on the camera and allow it to initialize. Once ready, the video feed will appear on the screen. The camera’s initial settings will be displayed for the first five seconds.

  5. Adjust Output Settings – Use the OSD (On-Screen Display) menu or the web interface to configure the output resolution and frame rate. For detailed instructions, refer to the Web Interface Configuration and System Menu section of this guide.

Recommended SFP+ Modules: We recommend the Bolin SFP+ 12G Optical Module (Part No. B-OSM-12). Based on thorough testing, we also recommend modules from FS and LR-TECH. The LR-TECH LR-8910D-SDI-LR module, tested under serial number BS190909052, demonstrated exceptional performance.

 

NOTE: The Optical Fiber connection provides video only and does not support network/Ethernet connectivity or IP camera control. The Optical Fiber output uses the same resolution setting as the SDI outputs; these video outputs are not independent.

 

Bolin SFP+ 12G Optical Module (B-OSM-12) LC Duplex Fiber Connector 

 

CAUTION: Make sure you keep the LC connectors on the fiber cable and SFP modules covered when not in use. Leaving connectors uncovered could lead to damage and signal degradation.  
 

 

 

Audio Output

Connecting an Audio Source to the Camera

Follow these steps to properly connect and enable audio on the camera:

  1. Connect the breakout cable:
    Use the 10-pin LEMO to XLR breakout cable (BLA-10) or a compatible third-party breakout cable. Insert the male LEMO connector of the breakout cable into the female LEMO port labeled “Balanced Audio” on the back of the camera.

  2. Connect the audio source:
    Using standard XLR cables, connect the output of your audio source (such as a microphone, audio mixer, or amplifier) to the two female XLR connectors on the breakout cable.

  3. Enable audio input:
    The camera supports embedded balanced audio through its industry-standard 10-pin LEMO connector, which can be enabled in two ways:

    • Via the Web Interface: Go to AV Setup and Click on MUTE speaker icon to Enable. Choose either Mic or Line in level input as appropriate.

    • Via the On-Screen Display (OSD) Menu: Select SYSTEM > AUDIO > AUDIO: ON to Enable. Adjust the input type and gain settings as needed.

 

Once connected and enabled, the audio signal will be embedded into the camera’s HDMI, SDI, and IP streams for seamless integration.

 

IMPORTANT INFO: Audio and video are not synchronized. Minor audio-to-video latency variation may be observed, depending on system configuration.
This camera is optimized for Line Level audio. It does not include internal audio mixing or amplification. The audio signal passes through at the same level it is received. If a mic level signal is connected directly, the input level may be low. For proper performance, audio should be amplified before entering the camera or boosted on the receiving end.  

 

Control Input

 

The R9 PTZ cameras have multiple ways of being controlled that can be used simultaneously to provide the user with the flexibility they need for their setup. The control methods are as follows : 

 

Infrared (IR) Remote Controller

Using the IR Remote Control to Save and Recall Preset Positions

The IR Remote Control allows users to save camera positions as presets and recall them quickly.

Saving a Preset

  1. Adjust the camera to the desired position (pan, tilt, and zoom).

  2. Press and hold the [PRESET] button.

  3. While holding [PRESET], press one of the [POSITION] buttons (1–9) to save that position.

Recalling a Preset

  1. Press the corresponding [POSITION] button (1–9) to recall the saved camera position.

Resetting a Preset

  1. Press and hold the [RESET] button.

  2. While holding [RESET], press the [POSITION] button (1–9) that you want to clear.

Please Note:

Lightbox content

 

Bolin Control (Recommended)

Bolin Control is our native API. When used with the KBD Plus, it's the recommended connection method because it provides more functions than VISCA over IP and real-time feedback from the camera. To set it up, follow these steps:

  1. Connect the camera to the network by inserting one end of a CAT6 cable into the 10/100/1000 LAN port on the camera and the other end into a network switch.
  2. Configure the camera's IP address and network settings so it can communicate with your controller.
  3. Connect the KBD Plus to the same network using a CAT6 cable.
  4. Configure the KBD Plus's network settings, select Bolin Control as the protocol, and enter the camera's IP address

Lightbox content

 

VISCA over IP

Using VISCA over IP allows users to control the camera from anywhere on the same LAN. To set it up, follow these steps:

  1. Connect the camera to the network by inserting one end of a CAT6 cable into the 10/100/1000 LAN port on the camera and the other end into a network switch.

  2. Configure the camera’s IP address and network settings so it can communicate with your PTZ controller.

  3. Connect a PTZ controller that supports VISCA over IP to the same network using a CAT6 cable.

  4. Configure the controller’s network settings, then enter the camera’s IP address and VISCA over IP port number: 52381.

Lightbox content

 

ONVIF Protocol

Bolin PTZ cameras support ONVIF 2.4 (Profile S/T), ensuring compatibility with a wide range of third-party applications, including PTZ controllers and streaming software. These cameras use the standard ONVIF port 2000 for communication.

ONVIF compliance enables device discovery, video streaming, and PTZ control, making these cameras ideal for live production, broadcasting, and professional AV workflows.

 

Integrating with ONVIF-Supported Software:

  1. Ensure the camera is connected to the network and properly configured.
  2. Use an ONVIF-compliant application to detect the camera.
  3. Enter the camera’s IP address, ONVIF credentials (web login credentials), and port 2000 during setup.
  4. Configure video and PTZ settings as needed for the application.

Lightbox content

 

 
 

VISCA Serial Commands (RS-422/485)

The camera is equipped with an RS-422 port, which facilitates VISCA control over serial commands. This RS-422 port is also compatible with RS-485. The camera can be connected via a serial connection to a PTZ controller or a computer. This allows for the execution of pan, tilt, and zoom operations, as well as the performance of preset recalls.

 

CAUTION: When one connects the camera via serial to a Sony PTZ controller, it differs from the process with a non-Sony PTZ controller. It is crucial to verify the pin settings for the specific controller in use.

 

  1. The camera should be powered on, and the OSD menu should be opened or the Web Interface should be logged into using any web browser. Proceed to the system settings and adjust the baud rate to match that of the controller. The VISCA ID should be set to a number between 1 and 7.
  2. A standard terminated CAT5 or CAT6 cable can be used to directly connect the camera to the controller. Alternatively, the included RJ45 to RS422 Control Cable Adapter can be used to connect unterminated CAT5/CAT6 cables between the camera and controller. The pin connection diagrams provided below should be followed, taking into account the specific controller in use and the desired connection.

RS422_pin_out(2)

Use RS-422 (VISCA) / RS485 (PELCO P/D) 

For camera operations, the RS-422/485 port can be utilized to connect controllers, such as a joystick keyboard or a PC station. This allows for the effortless management of pan, tilt, and zoom functions, as well as access to all preset functions using the controller’s buttons.

To operate a PC station, it is essential to have a software application that is compatible with this unit.

 

SONY Keyboard RS422 Connection
Guide for Establishing RS422 Connection and Daisy Chain Configuration for Multiple Cameras with a SONY Controller.

VISCA (Non-Sony) Keyboard RS422 Connection
Guide for Establishing RS422 Connection and Daisy Chain Configuration for Multiple Cameras with a Non-Sony Controller:
 

The included extension cables, along with the RJ45 to RS422 Phoenix connector adapter, should be utilized to establish an RS422 connection for the control device.

 

PELCO P/D Keyboard RS485 Connection 
Important: Utilize RS422 ports when establishing an RS485 connection. Only employ TX+ and TX- for RS485 connections.

 

• Set the RS422 control method using the OSD menu or Web interface.
• Set the camera ID on the OSD menu using the remote controller.

• To ensure the settings have been applied, restart the camera by switching it off and then back on.
• Use a PELCO P/D compatible keyboard for seamless integration.
• Utilize preset # 95 on the keyboard to access/exit the camera OSD menu.
• Navigate the OSD menu using the joystick and buttons "OPEN" or "CLOSE."
• For the keyboard operation details, refer to the user manual of the specific keyboard in use.

 

PELCO RS485 Connection

 

 
 

 

 

Synchronization (Genlock)

Genlock (Generator Locking) is an external synchronization signal input, which supports BBS (Black Burst Sync) and tri-level synchronization. External synchronization (genlock) can be applied to achieve precise frequency-locked video signals where every device (audio and video) knows when a frame starts and ends. Genlock is an industry standard and conforms to SMPTE standards.

 

To connect a genlock signal to your camera, follow these steps:

  1. Connect one end of a 75-ohm SDI cable with BNC connectors into the "Genlock" port of the camera. 
  2. Connect the other end of the 75-ohm SDI cable with BNC connectors to a device that is outputting the Genlock signal or providing timing reference (Sync Generator, Video Switcher, Audio Mixer, etc...)
  3. Open the camera's OSD menu and turn on External Synchronization. Other Genlock settings can be configured in this menu as well.
CAUTION: Once the Genlock cable is connected, ensure that Genlock is enabled in the camera’s menu. Otherwise, the camera will not synchronize with the rest of the system. External synchronization is supported only via SDI. It is not possible to achieve synchronization through HDMI or IP video signals.

 

For detailed information on configuring Genlock, refer to the Genlock section of the Web GUI settings.

 

 

Tally Light 

Tally Light GPI I/O connection

The camera is equipped with two Tally lights, serving as visual indicators. When illuminated, these lights signal that the camera is actively operational. One front Tally light improves visibility, and an additional Tally light positioned behind the camera block improves rear visibility. To activate the camera's Tally Light function, you need a video switch and a keyboard (not included).

 

GPI connection with RS422 VISCA control connection
Cable Configuration: 

1. Set up a standardized RS-422 daisy chain control connection to seamlessly control multiple cameras from the keyboard controller. (For detailed RS422 control information, refer to the Keyboard Controller user guide.)
2. Established a Tally/Contact Function cable connection between the Keyboard Controller and the Video Switcher (Sony).

1. On the keyboard side, connect pins 1-8. On the Video Switch side, connect pins 1-9, excluding pin 8.

2. Link keyboard pin 8 with video switch pin 9.

3. Connect keyboard pin 1 to video, switch pin 1, pin 2 to pin 2, and continue similarly (you can decide the rest based on the pattern), ensuring pin 7 is connected to pin 7.

 

Set Up

1. GPI I/O Input Mode for Tally Signal from Video Switch:

 

a. Connect the camera to the keyboard using a standard RS-422 control cable.

b. Establish a connection between the keyboard and the video switch using a tally function cable.

c. Navigate to KEYBOARD SETTING > GPI I/O > Setting, and switch it to Input mode. Exit to the home directory.

d. After completing the above steps, you can switch between cameras using the video switch. For instance, selecting camera 1 on the video switch sends a tally signal to the keyboard via the tally function cable. The keyboard then transmits this tally signal to camera 1 through the standard RS-422 control cable, activating camera 1's tally light. The keyboard can now control camera 1's pan and zoom.

e. If you switch to camera 2 on the video switch, the tally light for camera 2 will turn on, and the tally light for camera 1 will turn off.

 

2. GPI I/O Output Mode for Tally Signal Sent by Keyboard Controller:


a. Connect the camera to the keyboard using a standard RS-422 control cable.
b. Navigate to KEYBOARD SETTING > GPI I/O > Setting, and switch it to Output mode. Exit directly to the home menu.
c. After completing the above operation, you can switch between different cameras using the keyboard. For instance, selecting camera 1 on the keyboard sends a tally signal to camera 1 via the standard RS-422 control cable. As a result, camera 1's tally light turns on, and the keyboard gains control over camera 1's pan and zoom.
d. If you switch to camera 2 on the keyboard, the tally light for camera 2 will turn on, and the tally light for camera 1 will turn off.

 

 

Web Interface Configuration

Once connected to the network, the camera can be configured and controlled through its web interface using any web browser that supports HTML5. The following sections describe the available web interface settings and functions.

 

Web Interface Login

To access the web interface, first ensure that the camera is connected to the network and that the computer is connected to the same network.

 

Factory-Default Camera Network Settings

By default, the camera is configured for DHCP and will automatically obtain an IP address from the network’s DHCP server.

 

NOTE: The IP address assigned to the camera may vary depending on the network. Use the camera’s OSD Status page, your network’s DHCP client list, or the Bolin Discovery Tool to locate the camera’s current IP address.

 

 

Enter the camera’s IP address in your web browser to open the login page.

Use the default credentials:

Note: On your first login, you will be prompted to create a new password. For best security, use at least 8 characters and include one uppercase letter, one lowercase letter, one number, and one symbol.

 

Click Login to continue.

 

 

Live View

Once logged in to the camera,  the home page is the Live View page.

 

NOTE: This feed will be delayed by 1–2 seconds.

 

 

Adjusting and Controlling PTZ Functions

On the “Live View” page, the user will observe a “Menu” icon situated at the bottom right of the live view image. Additionally, on the right side of the page, there are “Pan/Tilt Controls”. This section comprises a set of arrows and sliders, specifically designed to control the camera.

The arrows are utilized to pan (move side to side) and tilt (move up and down) the camera. The focus and zoom buttons are provided for the user to adjust the view. The user can zoom in (+) or out (-), and manually adjust the focus to be closer (+) or further (-).

 

Furthermore, there are speed-setting sliders that permit the user to alter the speed of the camera’s movements, including pan, tilt, focus, and zoom. This allows the user to customize the camera’s operations to suit their needs.

 

Within the PTZ Setting drop-down menu, the user will discover the following options:

  1. Auto-Scanning: The camera image pans automatically from left to right or right to left at a speed defined by the user (Speeds 1-8).
  2. Preset: The user can set and recall up to 64 camera presets (The camera supports saving a total of 255 presets). These presets can be recalled through the web interface, IR Remote, or PTZ Controller.
  3. Tracking: The camera will record a series of presets that are recalled in a specified order.
  4. Scanning: The camera image pans from left to right or right to left between up to 12 points defined by the user at a speed also defined by the user (Speeds 1-8).
  5. Power On Action: Users can define a set of actions that a camera performs (preset recall, scan, trace, or cruise) once powered on.
  6. Cruise: The camera will record a series of movements that an operator makes, which can then be recalled whenever a user prefers.

Creating and Recalling Presets

To save presets, the user should adhere to the following steps:

  1. Utilize the PTZ controls of the web interface, IR controller, or a PTZ controller to adjust the camera to the position(s) they wish to save as a preset.
  2. After positioning the camera, click on the ‘Create’ button. Subsequently, select the preset number under which they want to save this setting. Label the preset in the ‘Name’ field and click ‘Save’.
  3. To recall a preset, select the preset number on the Web Interface and click the “Go” button.
  4. A saved preset can also be deleted by selecting it and clicking on the Delete button.

Adjusting OSD Menu Settings from the Web Interface

The OSD Menu settings can be accessed and adjusted from the Web Interface. On the “Live View” page, locate and click the “Menu” icon situated at the bottom right of the live view image to display the OSD menu. The user can navigate through these settings using the arrows under “Pan/Tilt Control”. The middle button is used to select, and the right arrow button is used to modify the setting. To exit this menu, simply click on the “Menu” icon again. The settings available in this menu encompass:

Lightbox content

 

 General Settings

 

Dashboard

The Dashboard page provides an overview of the camera’s current configuration, firmware information, device details, and operating status.

 

 

Lightbox content

 

Output

Allows you to configure the camera’s digital video output resolution and frame rate. Select the desired output format from the Resolution drop-down menu, then click Apply to save the setting.

 

 

Lightbox content

 

Genlock

The Genlock page provides controls for synchronizing the camera’s video output with an external reference signal. Before enabling Genlock, connect the camera to a compatible external sync generator.

The page displays the current Genlock Status and detected Reference Signal. Use the H Phase control to adjust the horizontal timing phase and fine-tune synchronization with other video equipment in the system.

 

 

Lightbox content

 

Image Settings

Monitor

The Monitor page provides a live preview of the camera’s video output and displays real-time operating information. Use the output selection menu to choose the video source to monitor, such as IP/HDMI or SDI, then click Apply to update the displayed information. You can also select which real-time information is displayed on the video output and choose between Fahrenheit and Celsius for temperature readings.

 

 

Lightbox content

 

OSD Overlay

Allows you to configure the camera’s digital video output resolution and frame rate. Select the desired output format from the Resolution drop-down menu, then click Apply to save the setting.

 

 

Lightbox content

 

AV Setup

 

Streaming Server

The Streaming Server allows you to configure the camera’s network streaming protocols for the Main Stream and Sub Stream. Available streaming options include RTSP, RTMP, SRT, MPEG-TS over UDP, and MPEG-TS over RTP.

Use the toggle next to each protocol to enable or disable the stream. The page also displays the assigned stream name and port number for each protocol. Select Edit to configure the individual streaming parameters and destination settings as required.

 

 

RTSP Stream ( example: rtsp://192.168.0.13:554/media/video1 ) RTMP Stream ( rtmp:// )
SRT Stream ( example: srt://192.168.0.13:8001?streamid=live/channel/0 ) 

MPEG-TS over UDP ( udp://@224.0.3.1:7000 ) 

MPEG-TS over RTP ( rtp://@224.0.3.3:7004 )

 

Lightbox content

 

NDI

The NDI tab allows you to configure the camera’s NDI streaming, discovery, and bridge settings. From this page, you can enable or disable the NDI Encoder, assign the NDI Name and Channel Name, configure Multicast settings, adjust the NDI HX Bandwidth, and select the supported NDI | HX mode.

The Web Control option enables NDI-based camera control, while Failover allows an alternate NDI source to be configured if required.

The Access Manager section provides NDI network management options, including the Group Name, Discovery Server, and NDI Discovery Server IP Address.

The Bridge section allows the camera to connect through an NDI Bridge configuration. When enabled, you can define the Bridge Name, Server IP Address, Port, and Key required for the connection.

After making any changes, click Apply to save the configuration.

 

Lightbox content

 

Code

The Codec allows you to configure the video encoding parameters for the camera’s Main Stream and Sub Stream. Available settings include Video Compression, Resolution, Frame Rate, Bitrate Type, Bit Rate, and I-Frame Interval, allowing each stream to be optimized for image quality, bandwidth, and application requirements.

The Ultra Low Latency option can be enabled to minimize video delay. When enabled, OSD overlays are disabled and the output resolution is fixed to 1080p. Select Apply to save changes or Default to restore the codec settings to their default values.

 

 

The Codec page allows you to configure the video encoding parameters for the camera’s Main Stream and Sub Stream. These settings determine the video compression format, resolution, frame rate, bitrate, and keyframe behavior used when streaming video over the network.

 

Ultra Low Latency

Enable Ultra Low Latency to reduce video transmission delay for applications where minimal latency is required.

 

NOTE: When Ultra Low Latency is enabled, OSD overlays are disabled and the video resolution is fixed to 1080P.

 

Main Stream and Sub Stream

The Main Stream is typically used as the primary, higher-quality video stream for viewing, recording, or production.

The Sub Stream provides a lower-resolution, lower-bandwidth stream that may be used for monitoring, previewing, or applications where reduced network bandwidth is preferred.

 

Stream Type

Displays the stream operating mode. Depending on the camera configuration, this setting may be fixed and unavailable for adjustment.

 

Video Compression

Select the video compression codec used to encode the stream.

Options:

Video compression reduces the amount of data required to transmit video over a network while maintaining image quality. Higher compression efficiency can reduce bandwidth and storage requirements.

H.265 (HEVC) is recommended when lower bandwidth usage is desired and the receiving device or software supports H.265.

Feature H.264 (AVC) H.265 (HEVC)
720P Bandwidth Reference Approximately 3 Mbps Approximately 1.5 Mbps
1080P Bandwidth Reference Approximately 6 Mbps Approximately 1.5 Mbp
4K Bandwidth Reference Approximately 32 Mbps Approximately 15 Mbps
Intraframe Prediction Modes 9 Modes 35 Modes
Color Depth 8-Bit Up to 10-Bit

 

NOTE: The bandwidth values above are general reference values only. Actual bandwidth requirements vary depending on the configured bitrate, frame rate, resolution, scene complexity, motion, and network conditions.

 

Resolution

Select the output resolution for each stream. Higher resolutions provide greater image detail but generally require more network bandwidth and processing resources.

Typical bitrate ranges may include:

Quality Resolution Typical Bitrate Range
720P 1280 × 720 1200–4000 Kbps
1080P 1920 × 1080 4000–8000 Kbps
4K 3840 × 2160 8000–14000 Kbps

 

NOTE: Available resolutions may vary depending on the selected codec, frame rate, operating mode, and camera model.

 

Frame Rate (FPS)

Select the number of video frames transmitted each second.

Available frame rates depend on the selected resolution and camera configuration and may include standard rates such as 29.97, 30, 50, 59.94, and 60 FPS.

Higher frame rates provide smoother motion, particularly in scenes with fast movement, but also increase bandwidth and processing requirements.

When selecting a frame rate, consider the available network bandwidth and the requirements of the receiving device or platform.

 

BP Frame

The BP Frame setting controls the frame structure used during video compression. Depending on the selected codec or operating mode, this setting may be automatically configured and unavailable for adjustment.

If the option is unavailable, it will appear grayed out.

 

Bitrate Type

Select how the camera controls the amount of data used to encode the video stream.

CBR – Constant Bitrate:
Maintains a relatively consistent bitrate throughout the stream. CBR is useful when predictable network bandwidth usage is required.

VBR – Variable Bitrate:
Adjusts the bitrate according to the complexity and amount of motion in the scene. VBR can reduce bandwidth during simple or static scenes while allocating additional data when more detail is required.

 

Bit Rate (Kbps)

Sets the amount of data allocated to the encoded video stream and is measured in Kbps (kilobits per second).

A higher bitrate generally provides greater image quality because more video data is retained. However, higher bitrates also require additional network bandwidth.

If the bitrate is set too low for the selected resolution and frame rate, image quality may be reduced or compression artifacts may become visible. If the bitrate is set unnecessarily high, the stream may consume excessive bandwidth and could cause buffering or playback issues on networks or receiving devices with limited capacity.

When configuring remote video transmission, ensure the available network bandwidth is greater than the combined bitrate of all active video streams.

 

I-Frame Interval

Sets the interval between I-frames (Intra-frames) in the encoded video stream.

An I-frame contains a complete image, while the frames between I-frames primarily contain information describing changes from previous frames. Increasing the frequency of I-frames can improve stream recovery and image refresh during scenes with significant movement, but it also increases bandwidth usage.

A lower I-frame interval produces I-frames more frequently, while a higher interval reduces their frequency.

For general operation, it is recommended to set the I-Frame Interval to approximately the same value as the configured frame rate. For example, when using 30 FPS, an I-Frame Interval of approximately 30 may be used.

 

Apply / Default

 

Lightbox content

 

Audio

The Audio allows you to configure the camera’s audio input settings. Use Audio Input to mute or enable audio, and select the appropriate Audio Input Type for the connected source.

Additional settings include Audio Compression, Bit Rate, Sampling Rate, and Input Volume for adjusting audio quality and input level. Phantom Power can also be enabled when required by a compatible microphone. Select Apply to save the audio configuration.

 

NOTE: This camera is optimized for Line Level audio. It does not include internal audio mixing or amplification. The audio signal passes through at the same level it is received. If a mic level signal is connected directly, the input level may be low. For proper performance, audio should be amplified before entering the camera or boosted on the receiving end.  

 

 

Lightbox content

 

Network Settings

 

Network

The Network page allows you to configure the camera’s IP network parameters. By default, the camera is assigned the static IP address 192.168.0.13.

Use Pattern to select the desired addressing mode, such as DHCP, and view or configure settings including IP Address, Subnet Mask, Default Gateway, Preferred DNS Server, Alternate DNS Server, and MAC Address.

When DHCP Fallback is enabled, the camera can use the configured fallback IP Address, Subnet Mask, and Gateway if a DHCP address is not obtained within the specified Timeout period. Select Apply to save the network configuration.

 

 

Lightbox content

 

Port

The Port allows you to view and configure the communication ports used by the camera for network control, streaming, and web access.

Available settings include TCP Port, UDP Port, RTSP Port, VISCA over IP Port, ONVIF Port, and HTTP Port. These port numbers determine which network ports are used by the corresponding protocols and services. Select Apply to save any changes.

 

 

The Port tab provides the following configuration options:

 

RTSP (Real-Time Streaming Protocol)

 

Use the RTSP tab to Copy the URL streaming address of the Main or Sub Streams. Paste the RTSP URL address in the Network Stream section of the VLC Media Player (or other video streaming software) to play video in real-time.

 

RTMP (Real-Time Messaging Protocol)

 

Navigate to the RTMP tab to stream or publish a video to a CDN (Content Delivery Network) or a cloud platform. You can obtain the URL stream and key number from an online platform such as YouTube or Twitch, usually found under Stream Settings in YouTube Studio.

 

FTP (File Transfer Protocol)

 

  1. Enable the FTP server.
  2. Enter the IP address of the FTP server into the ‘Server IP’ field.
  3. Enter the FTP server’s port number into the ‘Server Port’ field. This should match the port configured on the FTP server, typically port 21.
  4. Enter the FTP server’s username and password into the ‘Server Username’ and ‘Server Password’ fields, respectively. These credentials should match those configured on the FTP server.
  5. Choose the ‘Path Type’ and ‘Path’ where you want the snapshot to be saved on the FTP server.

 

Multicast On this page, users can configure multicast for both the Main and Sub streams. This is particularly useful for conserving bandwidth in live-streaming applications. 

 

  1. Follow the specified Multicast address range to configure a multicast IP address for the Main Stream.
  2. Follow the specified Multicast Port range to configure a multicast port for the Main Stream.
  3. Click the ‘Apply’ button and restart the camera to ensure the settings take effect.
  4. After the camera completes its power cycle, click the ‘Copy’ button to copy the multicast URL address. This URL can be used for accessing the Main Stream.
NOTE: Multicast streaming uses MPEG-TS over UDP.

 

SRT (Secure Reliable Transport)

 

NOTE: AES Encryption is available for all three modes (Caller, Listener and Rendezvous) and can be adjusted to: 128,192 or 256-bit encryption to ensure end to end security (no passphrase is required).

 

Lightbox content

 

Tracking Data Output

The Tracking Data Output page under Network Setting allows you to configure the camera to transmit tracking data over the network. Enable the feature, then enter the Destination IP Address and UDP Port Number of the receiving device or software.

Use Transfer Mode to define when tracking data is transmitted, and assign a Camera ID to identify the camera in multi-camera systems. Select Apply to save the tracking data output settings.

 

 

Lightbox content

 

System Settings

 

Firmware

The Firmware page displays the camera’s current system and firmware information. This section includes the Firmware Version, Product Serial Number, IP Encoder Version, MCU Firmware Version, and FPGA Version.

Use this information when verifying the camera’s software versions, checking compatibility, or providing system details for technical support and troubleshooting.

 

 

Firmware Update

 

To update the camera firmware, follow these steps:

  1. Visit Bolin Technology’s official website at www.BolinTechnology.com.

  2. Navigate to Resources and select Download Center.

  3. Enter the camera model number in the search field, select the corresponding device from the results, and open the Software section.

  4. Locate PTZ Camera FW Upgrade and click the Download icon. The firmware file will download automatically.

  5. Access the camera’s Web Interface, then navigate to System Settings > Maintenance.

  6. Under Firmware Update, either drag and drop the downloaded firmware file into the designated area or click Browse to manually select the file.

  7. Once the camera verifies that the firmware file is valid, click Update to begin the firmware upgrade.

Important: During the firmware update, do not close or refresh the browser, navigate away from the page, power off the camera, or disconnect the network connection. Interrupting the update process may cause the firmware upgrade to fail.
  1. After the firmware update is successfully installed, the camera will automatically restart. Allow the camera to complete this reboot and fully initialize.

  2. After the automatic restart is complete, it is recommended to perform a manual power cycle by disconnecting power from the camera, waiting a few seconds, and then reconnecting power. This helps ensure the updated firmware initializes correctly.

  3. Once the camera has restarted, log back into the Web Interface and verify the new Firmware Version under System Settings > Firmware.

 

Lightbox content

 

User

The User page under System Settings allows you to view and manage user accounts that have access to the camera. The User Management table displays each account’s Username, Role, User Permissions, and available Operations.

The default admin account has Administrator privileges, including access to functions such as Firmware Update and PTZ Control. Select Add users to create additional user accounts and assign the appropriate access permissions.

 

 

Lightbox content

 

Logs

The Logs tab displays system events generated by the camera, helping users monitor device activity and troubleshoot potential issues. Each log entry includes the event level, event number, date and time, and detailed event information, such as user login/logout activity, network IP assignments, and system startup events.

Use the All, Information, Warning, and Error filters to display specific types of events. The Clear button removes the current log entries, Export saves the logs to a file for troubleshooting or technical support, and Report generates a report containing the recorded system events.

 

 

Lightbox content

 

Date & Time

The Date & Time tab allows you to configure the camera’s system clock, date and time display formats, network time synchronization, and time zone.

The Current Time field displays the camera’s present system time. Enable Sync With Computer Time to synchronize the camera’s clock with the connected computer. Use the Date Format and Time Format drop-down menus to select how the date and time are displayed.

Enable Network Time Sync to automatically synchronize the camera with an NTP (Network Time Protocol) server. Enter the desired NTP server address, such as pool.ntp.org, and click Apply to save the settings.

Use the Time Zone drop-down menu to select the appropriate local time zone, then click Apply to save the time zone setting.

 

 

Lightbox content

 

The Reset tab provides options to restart the camera or restore the device to its factory-default settings.

Use Manual Restart > Reboot to restart the camera without changing the current configuration.

Under Default Setting, click Reset to restore the camera to its factory-default settings. Enable Keep Network Configuration if you want to preserve the camera’s existing network settings during the reset.

NOTE: Restoring the device to factory defaults will also reset the login password to its default setting.

 

 

Lightbox content

 

Discovery Tool

The Bolin Discovery Tool is a utility available for both Windows and macOS that is designed to detect and manage Bolin cameras on a network. It allows users to quickly discover connected Bolin devices, view key information such as the IP address, MAC address, model number, serial number, and firmware version, and launch the camera's web interface directly from the application. The tool also provides the ability to reset a camera's password when needed.

 

 

If the password to the camera has been lost or forgotten, follow the steps below to reset it:

  1. Download the Bolin Discovery Tool:

    • Visit the Download Center.
    • Search for the camera model SKU number.
    • Download the Bolin Discovery Tool to the computer.
  2. Run the Bolin Discovery Tool:

    • After downloading, open the Bolin Discovery Tool.
    • The tool will automatically detect any Bolin cameras connected to the network. 
  3. Select the Camera:

    • In the tool, locate and highlight the camera.
    • Right-click on the camera and select "Forgot Password" from the context menu. 
  4. Generate Reset Code:

    • A new window will appear with device information.
    • Click on "Generate Reset Code".
    • This will generate a unique code. 
  5. Contact Support:

  6. Login and Set a New Password:

    • Access the camera’s web login page.
    • Enter the temp password provided by the support team.
    • A prompt will appear confirming the password reset. 
    • The password has now been reset to the factory default: admin
    • Entering old password " admin " 
    • Enter a new password. The password must be 8-16 characters in length and should contain numbers, letters and special characters. Please note this password and save it in a secure place.
 

 

Lightbox content

 

System Menus

 

R9 -420N OSD Menu Structure

 

Exposure Mode: Full Auto High Sensitivity

Off, On

    Slow Shutter

Off, On

    S. Shutter Limit

1/1 - 1/50

    Gain Limit 9DB, 12DB, 15DB, 18DB, 21DB, 24DB, 27DB, 30DB, 33DB, 36DB, 39DB, 42DB, 45DB, 48DB 
    Gain Point Off, On
    Point Position 0DB, 3DB, 6DB, 9DB, 12DB, 15DB, 18DB, 21DB, 24DB, 27DB, 30DB, 33DB, 36DB
    Max. Speed 1/100 - 1/10K (1/100 level determined by the Min. Speed setting)
    Min. Speed

1/25, 1/30-1/10K (1/10K level is determined by the Max Speed setting)

    Backlight Off, On
    Spotlight Off, On
    AE Speed

1-48

    Ex. Comp

Off, On

    Ex. Comp Level -10.5, -9, -7.5, -6, -4.5, -3, -1.5, 0, +1.5, +3, +4.5, +6, +7.5, +9, +10.5   
  Mode: Manual High Sensitivity Off, On
    Gain 0dB, 3dB, 6dB, 9DB, 12DB, 15DB, 18DB, 21DB, 24DB, 27DB, 30DB, 33DB, 36DB, 39DB, 42DB, 45DB, 48DB
    Speed

50P, 25P, 50I-  1/1、2/3、1/2、1/3、1/4、1/6、1/8、1/12、1/15、1/20、1/25、1/30、1/50、1/60、1/100、1/120、1/150,1/215,1/300、1/425、1/600、1/1000、1/1250、1/1750、1/2500、1/2500、1/3500、1/6000、1/6000、1/10K

 

30P, 59.94i, 29.97P, 59.94P 60I, 60P -  1/1、2/3、1/2、1/3、1/4、1/6、1/8、1/10、1/15、1/20、1/30、1/50、1/60、1/90、1/100、1/125、1/180、1/250、1/350、1/500、1/725、1/725、1/1000、1/1500、1/2000、1/3000、1/4000、1/6000、1/6000、1/10K

    Iris

F2.8、F3.1、F3.4、F3.7、F4.0、F4.4、F4.8、F5.2、F5.6、F6.2、F6.8、F7.3、F8.0、F9.6、F10、F11

  Mode: Iris Priority Iris

F2.8、F3.1、F3.4、F3.7、F4.0、F4.4、F4.8、F5.2、F5.6、F6.2、F6.8、F7.3、F8.0、F9.6、F10、F11

    Gain Limit

9DB、12DB、15DB、18DB、21DB、24DB、27DB、30DB、33DB、36DB、39DB、42DB、45DB、48DB

    Gain Point Off, On
    Point Position

0DB、3DB、6DB、9DB、12DB、15DB、18DB、21DB、24DB、27DB、30DB、33DB、36DB

    Max Shutter 1/100 - 1/10K (1/100 level determined by the Min. Speed setting)
    Min Shutter 1/25, 1/30-1/10K (1/10K level is determined by the Max Speed setting)
    Backlight Off, On
    Spotlight Off, On
    AE Speed 01-48
    Ex-Comp Off, On
    Ex-Comp Level

-10.5、-9、-7.5、-6、-4.5、-3、-1.5、0、+1.5、+3、+4.5、+6、+7.5、+9、+10.5

  Mode: Shutter Priority Speed

50P, 25P, 50I-  1/1、2/3、1/2、1/3、1/4、1/6、1/8、1/12、1/15、1/20、1/25、1/30、1/50、1/60、1/100、1/120、1/150,1/215,1/300、1/425、1/600、1/1000、1/1250、1/1750、1/2500、1/2500、1/3500、1/6000、1/6000、1/10K

 

30P, 59.94i, 29.97P, 59.94P 60I, 60P -  1/1、2/3、1/2、1/3、1/4、1/6、1/8、1/10、1/15、1/20、1/30、1/50、1/60、1/90、1/100、1/125、1/180、1/250、1/350、1/500、1/725、1/725、1/1000、1/1500、1/2000、1/3000、1/4000、1/6000、1/6000、1/10K

    Gain Limit

9DB、12DB、15DB、18DB、21DB、24DB、27DB、30DB、33DB、36DB、39DB、42DB、45DB、48DB

    Backlight Off, On
    Spotlight Off, On
    AE Speed 01-48
    Ex-Comp Off, On
    Ex-Comp Level

-10.5、-9、-7.5、-6、-4.5、-3、-1.5、0、+1.5、+3、+4.5、+6、+7.5、+9、+10.5

  Mode: Bright High Sensitivity Off, On
    Level 05-37
  Mode: Gain Priority High Sensitivity Off, On
    Gain

0dB、3dB、6dB、9DB、12DB、15DB、18DB、21DB、24DB、27DB、30DB、33DB、36DB、39DB、42DB、45DB、48DB

    Gain Point Off, On
    Point Position

0DB、3DB、6DB、9DB、12DB、15DB、18DB、21DB、24DB、27DB、30DB、33DB、36DB

    Max Speed 1/100 - 1/10K (1/100 level determined by the Min. Speed setting)
    Min Speed 1/25, 1/30-1/10K (1/10K level is determined by the Max Speed setting)
    Backlight Off, On
    Spotlight Off, On
    AE Speed 01-46
    Ex-Comp Off, On
    Ex-Comp Level

-10.5、-9、-7.5、-6、-4.5、-3、-1.5、0、+1.5、+3、+4.5、+6、+7.5、+9、+10.5

White Balance Mode: Auto Speed 01 - 05
    Offset -7 - +7 
    Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 0 - 14
    Phase -7 - +7 
   

R-G

-99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: Indoor Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: Outdoor Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: OPW Offset -7 - +7
    Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: ATW Speed 01 - 05
    Offset -7 - +7
    Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: User R Gain 000 - 255
    B Gain 000 - 255
    Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: Outdoor Auto Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: SVL Auto Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: SVL Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
  Mode: SVL Outdoor A Matrix Off, On
    Select Standard, Fl. Light, High Saturation
    Level 00 - 14
    Phase -7 - +7
    R-G -99 - 0 - +99
    R-B -99 - 0 - +99
    G-R -99 - 0 - +99
    G-B -99 - 0 - +99
    B-R -99 - 0 - +99
    B-G -99 - 0 - +99
Detail Mode: Auto Level 00 - 15
  Mode: Manual Bandwidth Default, Low, Middle, High, Wide
    Sharpness 00 - 07
    H/V Balance -2 - +2
    B/W Balance Type 1 - Type 5
    Limit 00 -07
    Highlight Detail 00 -04
    Super Low 00 - 07
Picture   2D NR Off, 01 - 05
    3D NR Off, 01 - 05
    Flip Off, On
    Mirror Off, On
    ND Filter Off、1/4、1/16、1/64
    Effect Day, Night
    Chroma Suppress Off, Low, Middle, High
    HLC Mode Off, On
    Scenes Standard, Bright, Clarity, Soft
Gamma Standard Offset -64 - +64
    Level -7 - +7
    Black Gamma -7 - +7
    Black Gamma Range Low, Middle, High
    Black Level -48 - +48
    Visibility Enhancer Off, On
    VE Effect -3 - +3
  Straight Offset -64 - +64
    Level -7 - +7
    Black Gamma -7 - +7
    Black Gamma Range Low, Middle, High
    Black Level -48 - +48
    Visibility Enhancer Off, On
    VE Effect -3 - +3
  Pattern Pattern 00 - 51
    Pattern Fine 00 - 09
    Offset -64 - +64
    Level -7 - +7
    Black Gamma -7 - +7
    Black Gamma Range Low, Middle, High
    Black Level -48 - +48
    Visibility Enahncer Off, On
    VE Effect -3 - +3
Lens Zoom Ration OSD   Off, On
  AF Mode   Auto, Manual
  AF Sensitivity   Normal, Low
  MF Speed   00 - 07
  Near Limit   Over、8CM、10CM、14CM*、18CM、25CM、35CM、55CM、80CM、1.0M、1.2M、1.5M、2M、3M、5M
  Stabilizer   Off, On
Pan Tilt Adaptive P/T   Off, On
  P/T Speed   00 - 05
  Pan Direction   Normal, Invert
  Tilt Direction   Normal, Invert
  Preset Preset Memory Standard, Extended
    Preset Speed 00 - 05
    Motionless Preset Off, On
    Reload Preset 1 Off, On
Genlock H Phase   -127 - 0 - +127
System Pelco ID   001 - 255
  VISCA ID   001 - 007
  IR ID   01 - 03
  IR Receive   Off, On
  Comm Type   RS422
  Baud Rate   2400,4800,9600,38400
  Display Info   Off, On
  Video Parameters OSD   Off, On
  Tally Mode   Off, On
  Audio   Off, On
    Input Type Line
    Volume Level -60dB - +18dB (Increments of 2 dB)
    Phantom Power Off, On
  Color Space SDI YUV422
    HDMI RGB, YUV422
  System Format

2160P30

HDMI: 2160P30、1080P30

SDI: 2160P30、1080P30

    2160P29.97

HDMI:  2160P29.97、1080P29.97

SDI: 2160P29.97、1080P29.97

    2160P25

HDMI: 2160P25、1080P25

SDI: 2160P25、1080P25

    2160P24

HDMI: 2160P24、1080P24

SDI: 2160P24、1080P24

    2160P23.98

HDMI: 2160P23.98、1080P23.98

SDI: 2160P23.98、1080P23.98

    1080P60

HDMI: 1080P60、1080P30、1080i60、720P60

SDI: 1080P60、1080P30、1080i60、720P60

    1080P59.94

HDMI:  1080P59.94、1080P29.97、1080i59.94、720P59.94

SDI:  1080P59.94、1080P29.97、1080i59.94、720P59.94

    1080P50

HDMI:   1080P50、1080P25、1080i50、720P50

SDI:   1080P50、1080P25、1080i50、720P50

  Factory Reset   Yes, No
Status Pelco ID    
  VISCA ID    
  IR ID    
  Baud Rate    
  Comm Type    
  HDMI Format    
  SDI Format    
  FPGA FW    
  MCU FW    
  EXP Mode    
  WB Mode    
  Visibility Enhancer    
  Black Level    
  Matrix    
  Next Page    
  Adaptive P/T    
  Flip    
  Mirror    
  ND Filter    
  Stabilizer    
  P/T Speed    
  Preset Speed    
  IP Address    
  MAC Address    
  Previous Page    

 

 


 

Technical Specifications

 

R9-420N User Guide www.bolintechnology.com Bolin Technology

 

 